Description
– For use in potentially explosive atmospheres, e.g. laboratories, chemical plants, mills, paint finishing plants
– Universal installation position, vertical and horizontal
– Holding force of 9,000 N
– Monitoring contact as standard
The door strike must only be operated using the following individual parts:
– Power supply14.8 V, 160 mA
– EX-I switching amplifier type 9170/11-11-11S
TECHNICAL DATA ELECTRIC STRIKE EX138R——Z91
Marking:
II 2G Ex ib IIB T4 Gb
II 2D Ex ib IIIC 95 °C Db
Certificate: EU-Type Examination Certificate
Operating temperature: T4: -20ºC to +50ºC
Adjustable keeper (FF, FaFix®): Yes
Monitoring contact (RR): Yes
Diode (05): Yes
Fail-unlocked: Yes / 123 mA
Continuous duty: 14,8 V DC
Certified in compliance with: DIN EN 14846:2008
Load cycles for in-plant test: 250000
Installation position: Vertical and horizontal
Break-in resistance: 9000 N
Length: 76 mm
Connecting cable: 10 m
Suitable for fire doors: No
Width: 18 mm
FaFix® adjustment range: 3 mm
Depth: 25,5 mm
Latch bolt engaging depth: 6 mm
Scope of delivery: Delivery without striking plate with connecting cable
DIN direction: Universal
TECHNICAL DATA Ex i POWER SUPPLY 9143/10-156-160-10S
Marking:
II 3(2)G Ex nA [ib Gb] IIC/IIB T4 Gc
II (2)D [Ex ib Db] IIIC
I (M2) [Ex ib Mb] I
Certificate: EU-Type Examination Certificate
Power supply: 24 V AC / DC
Nominal voltage UN: 12.5 … 14.7 V
Max. nominal current IN: 140 mA
TECHNICAL DATA Ex i SWITCHING REPEATER 9170/11-11-11S
Marking:
II (1)G [Ex ia Ga] IIC
II (1)D [Ex ia Da] IIIC
Certificate: EU-Type Examination Certificate
Power supply: 24 V DC
Output / channel: 2 change-over contacts