Description
With a footprint diameter of only 30 mm, these ATEX Ex d pre wired photocells can be used in all types of applications and processes.
With a nominal range from 0,6 m to 15 m, it will be able to meet all needs.
TECHNICAL DATA
Marking:
Ex II 2GD
Ex d IIC T6 Gb
Ex tb IIIC T85ºC Db
Certificate: EU-Type Examination Certificate
Housing: Nickel platted brass. Stainless steel AISI 316L (in option)
Operating temperature: -20ºC to +55ºC
Ingress protection: IP67
Type of transmission: Infrared
Supply voltage: 12…24 VDC with protection against reverse polarity
Voltage limits (including ripple): 10…36 VDC
Current consumption: 35 mA
Switching capacity: ≤ 100 mA with overload and short-circuit protection
Voltage drop, close rate: 1,5 V
Maximum switching frequency: 500 Hz
Output state: Yellow LED
Electrical connection:
By cable 2m for XUWB..L2
By cable 5m for XUWB..L5 (in option)
Fixing diameter: M30x1,5
Additional information
Certified for use in: | Zone 1, Zone 21 |
---|